Abstract

AbstractElectron flux measurements are an important diagnostic for interactions between ultralow‐frequency (ULF) waves and relativistic (∼1 MeV) electrons. Since measurements are collected by particle detectors with finite energy channel width, they are affected by a phase mixing process that can obscure these interactions. We demonstrate that ultrahigh‐resolution electron measurements from the Magnetic Electron Ion Spectrometer on the Van Allen Probes mission—obtained using a data product that improves the energy resolution by roughly an order of magnitude—are crucial for understanding ULF wave‐particle interactions. In particular, the ultrahigh‐resolution measurements reveal a range of complex dynamics that cannot be resolved by standard measurements. Furthermore, the standard measurements provide estimates for the ULF flux modulation amplitude, period, and phase that may not be representative of true flux modulations, potentially leading to ambiguous conclusions concerning electron dynamics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.