Abstract

Piezoelectric sensor diagnosis and validity assessment as a prior component of structural health monitoring system are necessary in the practical application of electromechanical impedance technique. This article proposed an innovative sensor self-diagnosis process based on extracting the characterization of the real admittance (inverse of impedance) signature within a high-frequency range, which covered both diagnosis on damaged sensor after its installation and discrimination of sensor and structural damages during structural health monitoring process. Theoretical analysis was derived from the impedance model of piezoelectric-bonding layer-structure dynamic interaction system. Experimental investigations on piezoelectric sensor-bonded steel beam involved with structural damages of mass addition and notch damage were conducted to verify the process. It was found that the real admittance was reliable and critical in sensor diagnosis, and sensor faults of debonding, scratch, and breakage can be identified and differentiated from structural damage. Validity assessment of the diagnosed damaged sensor was addressed through resonant frequency shift method. The results showed that the validity of damaged sensor for structural health monitoring was inordinately depreciated by sensor damage. This article is expected to be useful for structural health monitoring application especially when damaged piezoelectric sensors existed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call