Abstract
To assess in diabetic nephropathy, the accuracy of estimated creatinine clearance (calculated with the Cockroft Gault formula) and the clearance of the Tc99m-DTPA, to measure the glomerular filtration rate (GFR). We analysed the GFR measure by Tc99m-DTPA method and the estimated by the Cockroft Gault formula, in 21 subjects with type 1 or type 2 diabetes. There was a strong positive correlation between the two methods but the Cockroft Gault formula underestimated the GFR. The formula gives a accurate estimates of GFR, when GFR is <100 ml/min/1,73 m2. Beside the underestimation, the formula could be used in the management of diabetic nephropathy because the repeated isotope assessments of renal function are impracticable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.