Abstract

To assess in diabetic nephropathy, the accuracy of estimated creatinine clearance (calculated with the Cockroft Gault formula) and the clearance of the Tc99m-DTPA, to measure the glomerular filtration rate (GFR). We analysed the GFR measure by Tc99m-DTPA method and the estimated by the Cockroft Gault formula, in 21 subjects with type 1 or type 2 diabetes. There was a strong positive correlation between the two methods but the Cockroft Gault formula underestimated the GFR. The formula gives a accurate estimates of GFR, when GFR is <100 ml/min/1,73 m2. Beside the underestimation, the formula could be used in the management of diabetic nephropathy because the repeated isotope assessments of renal function are impracticable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.