Abstract
Statement of problemObtaining a passive and well-adapted framework is challenging when intraoral scanning edentulous arches with multiple implants. The trueness of the printed casts is unclear. PurposeThe purpose of this clinical study was to evaluate the trueness of frameworks made from conventional and printed casts regarding clinical passivity and misfit. Material and methodsTen participants with complete mandibular fixed implant-supported interim prostheses retained by 4 implants were included. Each participant had a conventional impression and a digital scan made. The digital scan was made using an innovative device. Both conventional and digital casts were made, and the virtual images were used for milling the digital framework in cobalt chromium alloy. All frameworks were evaluated for passivity and marginal vertical misfit with the single screw test, with 4 attempts consisting of the tightened screw position, a test with all screws tightened, and an interspersed tightening test. The Kruskal-Wallis test was used to evaluate the trueness of the tested device for framework construction through the single screw test on vertical marginal misfit in the conventional and printed groups (α=.008). The Friedman test was used to assess the effect of test type (α=.05), and the Wilcoxon test was used to identify group-to-group differences (α=.017). ResultsThe absence of space between the framework and the abutments and interferences during its placement, as well as good stability, were observed clinically. In laboratory analysis, greater framework misfits were observed in the printed group compared with the conventional group when the single screw test was applied. Comparing the 3 tests used, the greatest misfits were observed when the framework was screwed onto the printed cast. ConclusionsThe innovative device tested for the intraoral scanning of multiple implants had clinically acceptable accuracy for the construction of passive and adapted frameworks. The conventional cast was more accurate than the printed cast, with lower misfit values, in all tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.