Abstract

Two variants of bunch length monitor (BLM) for the measurement of 1-5 mm RMS bunch length (/spl sigma//sub z/) are offered. The first one was designed for the measurement of a single bunch RMS. It consists of two cavities, each of them operates at two modes, E/sub 010/ and E/sub 110/. The second variant of BLM was designed for the measurement of a RMS of the bunches with repetition period less then 16 ns (series of identical bunches). There are two cavities in the BLM too. Loop coupling is used for the cavities and cavity-filters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.