Abstract

Background and objectiveThe prevalence of hospital-acquired infections (HAIs) is underreported in developing nations due to a lack of systematic active surveillance. This study reports the burden of device-associated HAIs (DA-HAIs) based on two years of active surveillance with in situ bundle care in closed intensive care units (ICUs) of a tertiary care hospital.Materials and methodsA prospective surveillance study was carried out in 140-bedded ICUs (2,100-bed hospital) of a tertiary care private medical college hospital. Daily active surveillance for catheter-associated urinary tract infection (CAUTI), ventilator-associated event (VAE), and central line-associated bloodstream infection (CLABSI) was done by trained infection control nurses (ICNs) along with quality champion nurses with HAI surveillance forms with bundle care auditing, which was attached to the case sheets of all patients on devices. The surveillance definitions of DA-HAIs were adapted from the Centers for Disease Control and Prevention (CDC)’s National Healthcare Safety Network (CDC-NHSN) 2017 surveillance criteria. Data were analyzed at the end of every month to generate the cumulative device-associated infection (DAI) rates and device utilization ratio (DUR). These data were compared with NHSN and International Nosocomial Infection Control Consortium (INICC) - India HAI rates and communicated to corresponding ICUs and also presented at the hospital infection control committee (HICC) meeting.ResultsThe surveillance data were reported over 71,877 patient days during the study period. The DUR of urinary catheters, ventilator, and central line were 0.53, 0.16, and 0.22, respectively. CAUTI, VAE, and CLABSI rates were 0.97, 10.5, and 0.43 per 1,000 device days, respectively. Among 166 DA-HAIs reported, 182 pathogens were identified. Klebsiella pneumoniae was the most common organism isolated, accounting for 37.4% of all DA-HAI cases, followed by Acinetobacter baumanii (30.8%). Most of the Gram-negative organisms were carbapenem-resistant (153/175; 87.4%). Vancomycin resistance rate in Enterococcus was 28.5% (2/7).ConclusionDUR and CAUTI, VAE, CLABSI rates were less/on par with the benchmarks of INICC and CDC-NHSN in almost all ICUs of our tertiary care unit. Gram-negative pathogen with 87.4% carbapenem resistance worsened the scenario. Proper active surveillance with bundle care and training by ICNs made a significant difference in all DA-HAI rates, especially VAE, which decreased to 10.5 from 23.6 per 1,000 ventilator days. Sustained active surveillance of HAI and bundle care auditing by a trained infection prevention team with a stringent antibiotic policy are the need of the hour to combat DAIs.

Highlights

  • The Centers for Disease Control and Prevention (CDC) defines healthcare-associated infections (HAIs) as complications or infections secondary to either device implantation or surgery [1]

  • Klebsiella pneumoniae was the most common organism isolated, accounting for 37.4% of all DA-hospital-acquired infections (HAIs) cases, followed by Acinetobacter baumanii (30.8%)

  • This study reports a two-year active surveillance data of device-associated HAIs (DA-HAIs) and device utilization ratio (DUR) with in situ bundle care with their organisms and their antimicrobial profile in the intensive care units (ICUs) of a tertiary care hospital in comparison with the CDC’s National Healthcare Safety Network (CDC-NHSN) and International Nosocomial Infection Control Consortium (INICC) - India HAI rates

Read more

Summary

Introduction

The Centers for Disease Control and Prevention (CDC) defines healthcare-associated infections (HAIs) as complications or infections secondary to either device implantation or surgery [1]. How to cite this article Ganesan V, Sundaramurthy R, Thiruvanamalai R, et al (November 07, 2021) Device-Associated Hospital-Acquired Infections: Does Active Surveillance With Bundle Care Offer a Pathway to Minimize Them?. The prevalence of HAIs is underreported in developing nations due to a lack of systematic active surveillance [5]. The prevalence of hospital-acquired infections (HAIs) is underreported in developing nations due to a lack of systematic active surveillance. This study reports the burden of device-associated HAIs (DA-HAIs) based on two years of active surveillance with in situ bundle care in closed intensive care units (ICUs) of a tertiary care hospital

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call