Abstract

In electrokinetically-driven microfluidic applications, reservoirs are indispensable and have finite sizes. During operating processes, as the liquid level in reservoirs keeps changing as time elapses, a backpressure is generated. Thus, the flow in microfluidic channels actually exhibits a combination of the electroosmotic flow and the time-dependent induced backpressure-driven flow. In this paper, a model is presented to describe the effect of the finite reservoir size on electroosmotic flow in a rectangular microchannel. Important parameters that describe the effect of finite reservoir size on flow characteristics are discussed. A new concept termed as “effective pumping period” is introduced to characterize the reservoir size effect. The proposed model identifies the mechanisms of the finite-reservoir size effects and is verified by experiment using the micro-PIV technique. The results reported in this study can be used for facilitating the design of microfluidic devices.