Abstract

This investigation was designed to explore the possibility of using transmission electron microscope (TEM) tomography on cement‐based systems gain a greater understanding of their nanostructure and pore network. The preliminary results show a clearly a well‐defined pore network at the nanoscale, with pore size approximately 1.7–2.4 nm in diameter and spaced around 5–8 nm apart. A comparison of small angle X‐ray scattering data with 2‐D TEM images analyzed with the Fourier slice theorem documents an excellent structural correlation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call