Abstract

This paper describes the design, construction, and performance of the wideband orthomode transducers (OMTs) for the L- (1.2–1.8 GHz), the S- (2–3 GHz) and the P- (0.56–1.12 GHz) band receiver systems of the Five-hundred-meter Aperture Spherical radio Telescope (FAST). These OMTs operate at the cryogenic temperature of 70K to reduce their thermal noise contribution to the receiver chains. The development on the FAST L- and S-band quad-ridged waveguide (QRWG) OMTs is carried out based on the theoretical mode analysis. In view of the miniaturization of FAST cryogenic receiver system at P-band, a novel wideband compact bowtie dipole OMT is designed with an octave bandwidth as well as a length of only quarter wavelength. The proposed L-, S- and P-band OMTs are designed and optimized by using Ansys High Frequency Structure Simulator (HFSS), and then manufactured, tested at room temperature. Measurement of FAST cryogenic receiver system noise is also performed with the L-, S- and P-band OMTs installed. The measured results fully comply with the design specifications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.