Abstract

A water leak detection method using krypton (Kr) as a water-soluble tracer has been proposed for fusion reactors with fully circulating the in-vessel cooling water. This method was targeted for applying to the International Thermonuclear Experimental Reactor (ITER), and the 10 −3 Pa m 3/s order of water leak valves were fabricated and connected to the water loop circuit. The water leaks were effused into the vacuum vessel evacuated by a cryopump and the water dissolved Kr was detected by a quadrupole mass spectrometer (QMS). When two leak valves with 1 m distance were attached to the test pipe with 30 °C heating, two distinct, the mass to charge number ratio ( m/ e) of 84 peak current rises caused by the water leak were successfully detected with the time interval of 39 s. On the other hand, the water accession length as a function of the traveling time was calculated by considering a natural convection flow caused by the 30 °C heating, where the traveling time was 44.6 s for the 1 m length. This means that the observed positional accuracy is 12.6%, based on the calculation. To enhance the positional accuracy, the detailed flow simulation is indispensable. This method can be applied to the ITER condition.