Abstract

We report the latest research development of vertical buffered electropolishing on its post-treatment procedure as well as the effects of several major post-treatment techniques for buffered electropolishing (BEP) processed 1.5 GHz niobium (Nb) superconducting radio frequency (SRF) cavities. With the established post-treatment procedure, an accelerating gradient of 28.4 MV/m is obtained on a single cell cavity of the cebaf shape. This is the best result in the history of BEP development. The cavity is limited by quench with a high quality factor over 1.2 × 1010 at the quench point. Analyses from optical inspection and temperature-mapping show that the quench should be originated from the pits that were already present on the cavity before this BEP treatment. All of these factors indicate that this procedure will have a great potential to produce better results if cavities without intrinsic performance limiting imperfections are used.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.