Abstract

With advanced high-strength steels and high value-added steels development, it is urgent to innovative run out table cooling line in hot strip mill with flexible cooling capacity to meet products metallurgical requirements of the cooling rate after rolling. The way to increase the cooling capacity is to improve the effect of heat exchange of water forced convection with hot strip. Then to raise the spraying pressure to penetrate the residual water and break the vapor inside it is the most feasible method. So, how to control the variable frequency device providing variable spraying pressure is the object of this study. Firstly, cooling after rolling process requirement under ultra fast cooling was analyzed; secondly, characteristic curves of centrifugal pump and water supply pipeline were tested; then inverter timing control, interlock control, security control and so on were studied. Since online application of the variable frequency control system, the water supply system has been running stably and reliably

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.