Abstract

Engineering Test Satellite VIII (ETS-VIII) is planning to be launched in 2005 for fundamental studies on satellite positioning technologies and is the one first to have installed a highly precise cesium clock in Japan. To measure the clock offset between the satellite and the TCE earth station, Time Comparison Equipment (TCE) has been developed by NICT. The TCE will be used to measure both code and carrier phases and this system will improve two-way time and frequency transfer. This equipment makes it possible to compare two clocks with high precision. Moreover, TCE and TCE earth stations have abilities to remove the delay caused by terrestrial ionosphere and that between the receivers and transmitters. We estimated measurement precision in code and carrier phases. Furthermore, from the examinations using TCE-EM (Engineering Model), we confirmed that TCE is able to measure the clock phases with a subnanosecond precision by code phase observation and a precision of a few picoseconds by carrier phase observation. © 2006 Wiley Periodicals, Inc. Electr Eng Jpn, 158(3): 61–71, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/eej.20385

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.