Abstract
We are developing thick intrinsic silicon detectors for hard X-ray and gamma-ray detection. The goal is to manufacture detectors with good spectroscopy and imaging capabilities without the need for cryogenics. Our current baseline design is a double-sided silicon strip detector with an active area of /spl sim/60 mm /spl times/60 mm and a thickness of 2 mm. To demonstrate the feasibility of 2 mm thick intrinsic detectors, we tested a 2 mm thick single pixel detector. An energy resolution of 1 keV FWHM at 60 keV was achieved at an operating temperature of -65C. The detector was fully depleted at /spl sim/800 V. We present the detailed results of tests on the pixel detector, the design of our double sided detector, and the conceptual design of hard X-ray and gamma ray instruments that use these detectors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.