Abstract

Developing countries face enormous challenges with substandard and falsified antimalarial drugs. One specific issue is the lack of a simple, cost-effective, and robust HPLC method to simultaneously determine and quantify the active pharmaceutical ingredients (APIs) in fixed-dose artemether-lumefantrine pharmaceutical dosage forms. The current study developed a novel, simple, sensitive, precise, accurate, and cost-effective RP-HPLC method for the simultaneous determination and quantification of artemether and lumefantrine in pharmaceutical dosage forms. The HPLC analysis was carried out on an Agilent 1260 Infinity Series HPLC system equipped with an ODS Intersil-C8 (150 × 4.6 mm) 5.0 µm column, by isocratic elution. The mobile phase composition consisted of acetonitrile and 0.05% orthophosphoric acid buffer of pH 3.5 in the ratio of 70 : 30 v/v. The analysis was performed at a 1 mL/min flow rate and a column temperature of 25°C. The total run time was 6 minutes. The detection was done with a variable wavelength detector (VWD) at an isosbestic point wavelength (λ) of 210 nm. The developed method was validated according to the ICH guidelines concerning system suitability, specificity, linearity, accuracy, precision, and robustness. The system suitability of the developed method revealed satisfactory theoretical plates and symmetry factors. The method proved to be specific, with no interference of mobile phase or excipients. The calibration plot exhibited linearity over the concentration range of 275-1925 μg/mL with R2 = 0.9992 for artemether and a range of 150-1050 μg/mL with R2 = 0.9985 for lumefantrine. The accuracy of the method, determined by the recovery study, was 99.79-100.16% for artemether and 99.04-99.50% for lumefantrine. The % RSD values for intraday precision were 0.175 and 0.203, while interday precision values were 0.340 and 0.554 for artemether and lumefantrine, respectively. The method demonstrated robustness when subjected to slight modifications in the flow rate, column temperature, and mobile phase composition. The developed analytical method proved satisfactory as per ICH guidelines and hence can be used for the determination and quantification of artemether and lumefantrine in bulk drug and pharmaceutical dosage forms.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.