Abstract

ABSTRACTIn a fuel handling system of sodium-cooled fast reactors (SFRs), it is necessary to remove the sodium remaining on spent fuel assemblies (FAs) before storing them in a spent fuel water pool (SFP). A next-generation SFR in Japan has adopted an advanced dry-cleaning system that consists of argon gas blowing to remove the metallic residual sodium on the FA, which increases economic competitiveness and reduces waste products thanks to a waterless process. In this R&D work, the performance of the dry cleaning process has been investigated.This paper describes experimental and analytical studies focusing on the amount of residual sodium remaining on a fuel pin bundle before and after the argon gas blowing process. The experiments were conducted using a sodium test loop and a short (approximately 1 m) specimen consisting of a 7-pin bundle. The effects of the blowing gas velocity and the blowing time were quantitatively analyzed in the experiments. The blowing gas velocity was varied from 3.9 to 31.3 m/s, and 113 data-points of the residual sodium were collected during the experiment. On the basis of these experimental results, the residual sodium quantification method for the fuel pin bundle was constructed.