Abstract

The ITER Poloidal Field (PF) magnet system consists of six coils. Niobium-Titanium (NbTi) is used as superconducting material and cable-in-conduit conductor(CICC) type are used as a conductor. All coils are fabricated by stacking 6 to 9 double-pancakes wound by two-in-hand winding scheme. The six PF coils (PF1 to PF6) are attached to the Toroidal Field (TF) coil cases through flexible plates or sliding supports to allow small radial and vertical displacements. The outer diameters of the coils vary between 8 m and 24 m. Since the PF coil system provides magnetic field for plasma shaping and position control together with the Central Solenoid (CS) coil, it needs to operate in fast pulse mode, leading to induced voltages of up to 14 kV on the coil terminals during operation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call