Abstract

In this study, a methodology was evaluated and improved to quickly measure the tensile strength of murine skin in a biomechanical assay for an incisional wound healing model. The aim was to streamline and enhance the wound model, skin specimen preparation, and tensile test so that large numbers of fresh tissue could be tested reliably and rapidly. Linear incisions of 25-mm length were made in the dorsal skin of mice along the spine and metallic staples were used to close the wound. After 20 days, the mice were sacrificed, and a square-shaped section of skin containing the linear incision was excised. Two metallic punches were fabricated and used to punch 15-mm long strips of skin of 2?mm width whose length was orthogonal to the direction of incision. The tensiometer configuration was modified to expedite tensile measurements on fresh skin, and load-to-failure was measured for each strip of skin from the cephalad to the caudal region. We evaluated sources of error in the animal model and the testing protocol and developed procedures to maximize speed and reproducibility in tensile strength measurements. This report provides guidance for efficient and reproducible tensile strength measurement of large numbers of skin specimens from freshly sacrificed animals.•Tattoo placement to identify the two ends of the healing incisional wound assisted in decreasing error in the position and orientation of tensile strips.•Custom-made punches to prepare skin strips for tensile testing helped conduct tensile tests of fresh tissue rapidly.•Alteration of the manual grips of the tensile tester enabled specimens to be gripped rapidly to significantly accelerate testing for each skin strip.

Highlights

  • In this study, a methodology was evaluated and improved to quickly measure the tensile strength of murine skin in a biomechanical assay for an incisional wound healing model

  • Biomechanical assays serve as useful techniques to determine the extent of skin wound healing and provide insight into the functionality of repaired skin compared with intact skin

  • The report summarizes modifications we made to a mouse skin incisional wound and to a protocol for tensile testing to ensure reproducibility and handling of large numbers of specimens

Read more

Summary

Introduction

A methodology was evaluated and improved to quickly measure the tensile strength of murine skin in a biomechanical assay for an incisional wound healing model. The aim was to streamline and enhance the wound model, skin specimen preparation, and tensile test so that large numbers of fresh tissue could be tested reliably and rapidly. Linear incisions of 25-mm length were made in the dorsal skin of mice along the spine and metallic staples were used to close the wound. We evaluated sources of error in the animal model and the testing protocol and developed procedures to maximize speed and reproducibility in tensile strength measurements. This report provides guidance for efficient and reproducible tensile strength measurement of large numbers of skin specimens from freshly sacrificed animals

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.