Abstract

Tumor targeting pharmaceuticals will play a crucial role in future pharma pipelines. The targeted thorium conjugate (TTC) therapeutic platform could provide real benefit to patients, whereby targeting moieties like monoclonal antibodies are radiolabelled with the alpha-emitting radionuclide thorium-227 (227Th, t1/2 = 18.7 days). A potential problem could be the accumulation of the long-lived daughter nuclide radium-223 (223Ra, t1/2 = 11.4 days) in the drug product during manufacturing and distribution. Therefore, the level of 223Ra must be standardized before administration to the patient. The focus in this study has been the removal of 223Ra, as the other progenies will have a very limited stay in the formulation. In this study, the purification of TTCs labeled with decayed 227Th has been explored. Columns packed with a strong cation exchange resin have been used to sequester 223Ra. The separation of TTC from 223Ra has been evaluated as influenced by both formulation and process parameters with a design of experiments (DOE) study; including citrate or acetate buffer, pH, buffer concentration, presence or absence of pABA + EDTA, resin amount and sodium chloride concentration. The aim was to achieve a separation with high sorption of 223Ra and accompanying low TTC sorption. The results were analyzed by multivariate analysis. Four regression models of TTC and 223Ra sorption from citrate and acetate buffered formulations were developed. The predictive accuracy of sorption in the four statistical models was given by standard deviations and confidence intervals. The TTC sorption in citrate and acetate buffered formulations was affected by the identical variables and the variation in TTC sorption was comparable for the two models. However, the DOE variables had a significantly stronger impact on the 223Ra sorption in citrate buffered formulations than the 223Ra sorption in acetate buffer. An optimal separation with a TTC sorption below 25% and 223Ra sorption above 90% can be achieved in both citrate and acetate buffered formulations. Stability studies of radiochemical purity (RCP) indicated that the measured 227Th values may be partly due to free 227Th and not TTC, but the results indicate that TTC stability may be controlled by optimizing formulation parameters. Hence, the sorption data and the regression models presented must be reviewed and further explored with regard to what is known about the stability of the TTC in the different buffered formulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.