This paper proposed the development of rotary fatigue test equipment. This equipment was used to test the JIS S45C steel, validated using the Joseph Marin approach. Analyzing the fatigue strength of JIS S45C steel using the Joseph Marin approach was compared to experimental testing. The dimension of the test specimens was based on the ASTM E 466. The test data was displayed in the form of an S-N curve. The test results showed the fatigue strength of JIS S45C steel on the whole that was close to each other, experimentally and using the Joseph Marin approach. In the infinite life region, it is known that the fatigue strength based on the Joseph Marin approach was lower than experimental tests. Therefore, if JIS S45C steel had received a hefty load repeatedly, it would fail more quickly.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.