Abstract

With the view of obtaining basic data required for designing durable reflux vapor traps of high performance for use in sodium-cooled FBR's, experiments were conducted to (a) select a suitable packing, and (b) to examine the effect brought on trapping performance by changing the gas flow rate, packing material, packing density and trap outlet temperature. The results indicated that: (1) As trap packing, plane weave stainless steel mesh proved to ensure lower pressure drop through trap. (2) Using the plane weave mesh packing, and with the trap outlet temperature kept at 130°C, the reflux vapor trap efficiency was found to exceed 99.6% in the range of vapor trap gas velocity below 1.3 m/s, and packing density below 0.07 g/cc. The efficiency decreased at outlet temperatures above 130°C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.