Abstract

Background: A new wearable pulse audiogram (PAG) of radial artery was developed with the main purpose to quickly screen atrial fibrillation (AF) and monitor pulse amplitude variation. Methods: Subjects with sinus rhythm (SR), AF, ectopic arrhythmia (EA), and a pacemaker rhythm (PM) were recruited to measure the PAG of radial artery. In total, 91 subjects were recruited: SR ( $n =45$ ), AF ( $n =21$ ), EA ( $n =11$ ), and PM ( $n =14$ ). For signal processing, the inter-pulse interval (IPI) and pulse height (PH) were extracted. Then, an automatic classification algorithm combining fuzzy c-means (FCM) or sample entropy (CEn) with an adaptive-network-based fuzzy inference system was constructed. The PAG data were divided into different segment lengths (10 to 30 beats) to investigate the robustness of the algorithm in short intervals. Furthermore, linear regression was performed to evaluate the relation between the normalized IPI and PH in the AF group. Results: The identification rate of AF increased with the number of beats and decreased with the number of classified types of arrhythmia. Results of combining CEn and FCM, or of FCM alone were better than those of CEn alone. When the combined method was used for the two types of arrhythmia and the number of beats was greater than 10, the rate of successful identification was greater than 90%, validating the technique. Furthermore, for the AF group, PH increased with IPI, while the amplitude of electrocardiogram (ECG) did not. Conclusions: Results indicated that our PAG can effectively identify AF, even in a time window as short as 10 beats. In addition, PAG can monitor the trend of pulse amplitude, possibility that cannot be offered by an ECG.

Highlights

  • A trial fibrillation (AF), the most common arrhythmia type with increasing age, accounts for 15% to 20% of ischemic strokes and contributes to higher mortality rates [1]

  • In the ectopic arrhythmia (EA) case, inter-pulse interval (IPI) was divided into three clusters, while in the sinus rhythm (SR) and pacemaker rhythm (PM) cases, IPI merged into one cluster

  • A new wearable pulse audiogram (PAG) of the radial artery was developed with the main purpose of quickly detecting atrial fibrillation (AF) and monitoring pulse amplitude variation

Read more

Summary

Introduction

A trial fibrillation (AF), the most common arrhythmia type with increasing age, accounts for 15% to 20% of ischemic strokes and contributes to higher mortality rates [1]. Methods: Subjects with sinus rhythm (SR), AF, ectopic arrhythmia (EA), and a pacemaker rhythm (PM) were recruited to measure the PAG of radial artery. Results: The identification rate of AF increased with the number of beats and decreased with the number of classified types of arrhythmia. When the combined method was used for the two types of arrhythmia and the number of beats was greater than 10, the rate of successful identification was greater than 90%, validating the technique. For the AF group, PH increased with IPI, while the amplitude of electrocardiogram (ECG) did not. PAG can monitor the trend of pulse amplitude, possibility that cannot be offered by an ECG

Objectives
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.