Abstract

Precision DC voltage dividers with ratings up to 1000 kV have been built using the 150 kV resistor module developed at the National Measurement Institute, Australia (NMIA). The structure of the 150 kV resistor module and the measurement techniques for evaluating its performance are described. The method for evaluating voltage ratio errors at voltages up to 1000 kV is discussed. It is shown that a ratio error of less than 5 μV/V at 150 kV and less than 100 μV/V at 1000 kV can be achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.