Abstract

To improve the spatial resolution of positron annihilation spectroscopy (PAS), a system to produce an intense positron microbeam was developed in AIST. A slow positron beam, which was produced by an electron linear accelerator, was focused by a lens onto a remoderator to enhance its brightness. The brightness-enhanced beam with an intensity of ≈1 × 106 e+/s was extracted from the remoderator and focused onto the sample by a lens. The beam size at the sample was 25 μm, which is more than two and half orders of magnitude smaller than that in the magnetic transport system (≈10 mm). Hence, the spatial resolution of PAS with an AIST positron microbeam can be drastically improved relative to PAS using conventional methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.