Abstract
The capability of natural circulation for core cooling has been evaluated in detail for a station blackout (SBO) event induced by an earthquake and a subsequent tsunami hit. The evaluation was prompted by the accident at the Fukushima Daiichi nuclear power station of Tokyo Electric Power Company. The plant dynamics computer code Super-COPD was used for the evaluation, which has been validated by analyses of preliminary test results on the natural circulation in Monju. As a result, it was concluded that natural circulation of the sodium coolant will enable the decay heat from the core to be removed under such an SBO condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.