Abstract

The ATPase assay system on pH stat apparatus was developed. For the ATPase activity measurement, hydrogen ion (H+) concentration delivered from inorganic phosphate (Pi) as a hydrolysis production of ATP was estimated by titrating with 20 mM NaOH solution instead of colorimetric measurement of Pi. Inclusion of 0.5 M KCl in the ATP stock solution and 2 mM Tris-maleate (pH 7.0) buffer in the reaction medium reduced the extent of pH change upon addition of ATP to initiate the ATPase reaction. The amount of H+ liberated from Pi was strongly affected by the set pH for the ATPase assay with a promotion at alkaline pH. Thus, it was required to estimate the coefficient to convert H+ to a Pi concentration at a specific pH. The specified coefficient at pH 7.0 was 1.248. ATPase assay on pH stat allowed us to follow the ATP hydrolysis by myofibrils continuously showing a curvature profile at low salt medium (≤0.2 M KCl) or a linear profile at high salt (≥0.3 M KCl).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.