Abstract

The present paper is a summary of experimental tests performed with microbulk Micromegas for application in a neutrinoless double beta decay experiment based in a xenon TPC. No critical limitation related with high pressure has been detected for Micromegas, which has been tested up to 10 bar. No significant differences have been found between low energy X-rays and high energy alpha tracks regarding ionization yield and electronic transparency of Micromegas mesh. Using 5.5 MeV alphas in argon-isobutane mixtures, values as low as 1.8% FWHM have been obtained, with possible evidence that better resolutions are achievable. These results seems independent of pressure (probed up to 4.5 bar) or gas mixture (microbulks have run in xenon without quencher). The imperative necessity of high quality gas led to start on a new TPC and MPGD dedicated lab at Zaragoza.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.