Abstract

In this study, a small-sized DC motor type axial mechanical testing machine was developed to be utilized for fatigue testing of electronic parts such as ICs, etc. Thermal fatigue cracking in a beam lead in /spl mu/BGA, a type of chip scale package (CSP), was identified as a major failure mode in the quality assurance test or in the field. The beam lead was made with copper foil. Thus, the reliability of the /spl mu/BGA was strongly dependent on the fatigue characteristics of the copper used. In this study, the four kinds of beam leads made by different processes, were tested to obtain the tensile strength and fatigue characteristics and compared them with each other. The tensile and fatigue strength of the beam lead fabricated by a chemical polishing process with dipping time of 50 min is the best among the beam leads tested. The result of this study enables us to estimate the reliability of the /spl mu/BGA without the temperature cycling test of a fully assembled /spl mu/BGA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.