Abstract
Acetamiprid development of moderate conditions of high-performance liquid chromatography method in the separation of biological fluids from blood and urine. The analysis (Shimadzu Corporation) was carried out on a high-performance liquid chromatograph SPD–M20A, equipped with a model LC-20 Prominence (US) diode matrix UV-detector autosamplers. The process consists of a four-channel gradient type pump designed for high-pressure operation, a spectrophotometric detector with a wavelength of 190–360 nm, and a measuring device with a volume of 20 μL – “Rheodyne” injector and a chromatographic column. The research was conducted under the following conditions: – Perfect Sil 300 ODS C18 with chromatographic steel column particle size 5 μm. Filled with the sorbent, size 150 × 4.6 mm; – excited phase acetonitrile-water 70:30; – reduction phase flow -0.75 ml/min; – Sample size for analysis – 20mkl; – detector wavelength 246 nm; – analysis time 10 minutes. Acetamiprid was weighed to 0.01 g (a.t), dissolved in a 50 mL volumetric flask with a mobile phase, and the volume of the solution was delivered by the mobile phase to the mark. From this solution, standard working solutions of acetamiprid were prepared and the separation time of acetamiprid was determined. As a result of the analysis, the retention time of acetamiprid on the chromatogram was 2.314 minutes in the blood and 2.722 minutes in the urine. The obtained results were determined by metrological analysis with 67.56% separation of acetamiprid from model blood samples with a relative error of 1.63%, with a relative error of 73.98% with acetamiprid of the model urine sample. The retention time of acetamiprid pesticide in the standard sample under the conditions developed by the HPLC method was 2,190 minutes. Chromatographic peaks were formed in the test blood sample, which lasted 2,314 minutes, and 2.722 minutes in the urine. The amount of acetamiprid isolated from model blood and urine samples was 67.56% in the blood and 73.28% in the urine during metrological analysis. Moderate conditions for the detection of acetamiprid by high-efficiency liquid chromatography have been developed. On the chromatogram, acetamiprid was identified by chromatographic peaks with a retention time of 2,190 minutes in standard samples. When the samples tested were also chromatographed, values equal to the retention time of standard acetamiprid were recorded. Under the conditions of the developed analysis, positive results were obtained and 67.56% of biological fluids were isolated from blood samples and 73.28% from urine samples. The developed methods of analysis were applied to the detection of biological fluids, and pesticides isolated from them.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.