Abstract

TFM (Total Focusing Method) is an advanced post-processing imaging algorithm of ultrasonic array data that shows good potential in defect detection and characterization. It can be employed using an infinite number of paths between transducer and focusing point. Depending upon the geometry and the characteristics of the defect in a given part, there are not the same modes that are appropriate for the defect reconstruction. Furthermore, non-physical indications can be observed, prone to misinterpretation. These imaging artifacts are due to the coexistence of several contributions involving several modes of propagation and interactions with possible defects and/or the geometry of the part. Two methods for filtering artifacts and reducing the number of TFM images are developed and illustrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.