Abstract

In order to improve the well-known short operational life time of BF3 counters, three potential adsorbents for impurity gases (graphite, activated charcoal and a zirconium-aluminum mixture) were introduced into BF3 counters in the form of coating on the aluminum cathode surface. Tests in γ fields revealed that a partial coating of activated charcoal provides the best result. The improvement of their operational life in γ fields was about three orders of magnitude in terms of tolerable exposure. Many counters with a partial coating of activated charcoal were further tested from the following viewpoints: background noise, vibration and shock, γ pulse discrimination, operational life in a neutron field and non-operational in-reactor exposure life. The results were satisfactory for reactor control and protection usage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.