Abstract

SummaryTwo types of intermittent wind tunnel drives, the pressure storage drive(with atmospheric exhaust) and the vacuum storage drive (with atmospheric inlet), are examined and found to match well the tunnel pressure ratio-mass flow characteristics over a wide Mach number range (0 to 4). The design of components of intermittent wind tunnel installations, their operation and instrumentation are then considered in some detail. In order to increase the output of intermittent wind tunnels to a level comparable to that of continuously running tunnels, it is proposed to drive the models during each tunnel run through a range of incidence. This technique is at present under development in the National Aeronautical Establishment's High Speed Aerodynamics Laboratory and results so far obtained are discussed. Two tunnels are considered as examples of large intermittent installations: a 4 ft. square pressure-driven tunnel and a 6 ft. square vacuum-driven tunnel. The former is found to be a more compact and economical installation. Relative merits of continuous and intermittent installations are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.