Abstract

As the most widely used construction material, concrete is very durable and can provide long service life without extensive maintenance. The strength and durability of concrete are primarily influenced by the initial water-cement ratio value (w/c), and the curing condition during the hardening process also influences its performance. The w/c value is defined as the total mass of free water that can be consumed by hydration divided by the total mass of cement and any additional pozzolanic material such as fly ash, slag, silica fume. Once placed, field concrete pavements are routinely cured with liquid membrane-forming compounds. For laboratory study, concrete samples are usually cured in saturated lime water or a curing room with a relative humidity (RH) value higher than 95%. Thus, the effectiveness of curing compounds for field concrete needs to be studied. In this study, the dielectric constant value of plastic concrete was measured by ground penetrating radar (GPR). The w/c value of the plastic concrete was calculated by a mathematical model from the measured dielectric constant value. The calculated w/c value was compared with the microwave oven drying measurement determined result in AASHTO T318. A modified coarse aggregate correction factor was proposed and applied in microwave oven drying measurement to determine the w/c value of plastic concrete in AASHTO T318. The effectiveness of curing compound was evaluated by field concrete slabs by GPR measurement. It was found that GPR can be a promising NDT method for In this study, the dielectric constant value of plastic concrete was measured by ground penetrating radar (GPR). The w/c value of the plastic concrete was calculated by a mathematical model from the measured dielectric constant value. The calculated w/c value was compared with the microwave oven drying measurement determined result in AASHTO T318. A modified coarse aggregate correction factor was proposed and applied in microwave oven drying measurement to determine the w/c value of plastic concrete in AASHTO T318. The effectiveness of curing compound was evaluated by field concrete slabs by GPR measurement. It was found that GPR can be a promising NDT method for w/c determination of plastic concrete and curing effectiveness evaluation method for hardened concrete.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.