Abstract

For many applications of RPCs to time-of-flight counters in heavy ion experiments the expansion to much higher values of the counting rate capability, so far limited to around 2kHz/cm2 is of fundamental importance. To address this issue we developed single-gap timing RPCs with resistive electrodes made from a commercially available plastic material. Tests performed in photon beams yielded a time resolution around 90ps σ, essentially unchanged from 2kHz/cm2 to 27kHz/cm2. This result establishes the basic feasibility of timing measurements with RPCs at rates of tens of kHz/cm2, keeping a time resolution below 100ps σ and using plastic electrode materials.