Abstract

A heat sink with ionic wind has been developed in this study for a new cooling device of a Light Emitting Diode (LED). The characteristics of the ionic wind using wire to parallel-plate-electrodes were analyzed using the Computational Fluid Dynamics (CFD) technique suggested in this study. Also, the cooling performance of the heat sink applied by the impinging flow of the ionic wind was investigated by parametric studies. The CFD results were verified from the experimental results of the ionic wind velocity and temperature. A developed prototype of the heat sink with the ionic wind was then manufactured and tested for its cooling performance. Finally, the advantages of the heat sink with the ionic wind for cooling the LED were confirmed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.