Abstract
In order to improve the sensitivity and the reliability of the sodium leak detection system used in the fast breeder reactors, a new type SID (sodium ionization detector) has been developed, in which the monitored signal is only the fluctuating component of the current between the filament and the ion collector. The fluctuating component was extracted by a band pass filter and its root mean square value was calculated as the SID signal. Fluctuation characteristics of the output current were studied by its frequency spectrum. The results revealed that the current spectrum was affected by the particle size distribution of the aerosol and was most clearly distinguished from that of the background current in the frequency region of 0.5–10 Hz. Output characteristics of the fluctuation monitor type SID (FM-SID) were obtained as a function of sodium concentration in the gas. The FM-SID sensitivity was lowered by impurities in the gas, such as oxygen and water vapor. Finally, in comparisons with the conventional DC-SIDs, the background noise level of the FM-SID was much lower and SIN ratio was greatly improved. The detectable sodium concentration level was ten times lower than that of the DC-SID.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.