Abstract

The compressor and fan in air conditioner outdoor unit are the core component which deter-mines noise performance as well as cooling or heating performance. Among these, the com-pressor has larger contribution to the noise of outdoor units. For high efficiency air condition-er, the size and operating speed of compressor are smaller and faster. The high-speed com-pressor causes loud noise which is complaints for the customer. Traditionally, it is well-known that the vibration of compressor and connected duct is main noise source. However, as the compressor speed increases, the refrigerant flow in the compressor discharge duct also emerged as a major noise source. To reduce the compressor noise operating at high speed, it is necessary to analyze vibrational and acoustic characteristics of compressor discharge duct. This duct noise has the two-types source: structure born noise and flow induced noise. The structure born noise is generated by the duct vibration caused by compressor movement. For the flow induced noise, the static pressure field of refrigerant flow in the duct is vibrational source. In this paper, the compressor discharge duct noise considering two mechanisms was investigated. The refrigerant flow is solved using CFD and duct vibration and noise radiation are computed by FE-BE method.