Abstract

In nuclear power plants (NPPs), concrete containment buildings (CCBs) provide the final physical barrier against the release of radioactive materials into the environment and protect the nuclear structures housed within the containment building. CCBs have to be maintained to ensure leak tightness and sound structural integrity for the safe operation throughout the life of NPPs. However, the integrity of CCBs may be affected by the ageing of its concrete, post-tensioning cables and reinforcing bars (rebars). Finite element models (FEMs) of CANDU 6 CCBs have been developed using 2 independent finite element programs for the study of the effect of ageing of CCBs. These FEMs have been validated using multiple-source data and have been used for preliminary analyses of the effect of thermal load and ageing degradation on the concrete structure. The modelling assumptions and simplifications, approach, and validation are discussed in this paper. The preliminary analyses for temperature effects and potential applications to the study of ageing degradation in CCBs using the FEMs are briefly introduced.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call