We have developed a radiation monitor by using plastic scintillation fibers (PSF), which we call the fiber optic radiation monitor. For wide-area radiation monitoring, the detection part needs to be longer, therefore we have produced a prototype monitor by combining the PSF and the silica fiber for optical propagation.In this paper we first explain the characteristics when silica fiber of 100 m long is connected to the PSF. We found that in this case, the position resolution would drop. In order to determine the cause, we observed the aspects of optical pulse propagation. It was found that the light is transmitted through the silica fiber and is detected at fiber end as single photons, and the resolution deteriorated due to the difference in the propagation path of each of photons.We next explain the prototype fiber optic radiation monitor with a detection length of 20 m and a total length of 60 m, and its performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.