Abstract

A fast response calorimeter has been developed for the neutral-beam (NB) shine-through measurement. This calorimeter has the following advantages. (1) Temporal variation of the heat load onto the calorimeter can be measured. (2) Measurement under the relatively high heat flux environment is possible. (3) The calorimetric measurement under continuous and steady-state heat load environment is also possible. The verification of the measurement principle was done using an NB-injection system on the compact helical system (CHS) at the National Institute for Fusion Science (NIFS). The measured NB power densities are compared to the power densities being evaluated by the CHS-NB profile database. It was experimentally confirmed that the time constant of the measurement is about 7 ms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.