Abstract
The load separation method was employed to measure the pl η -factor, the growing crack length and the applied J-integral during the course of the test of small curved CT specimen of Z-2.5Nb pressure tube material. The effect of the notch tip radius of the notched (reference) CT specimen on the separation parameter was analyzed to predict the crack growing length in the precracked specimen. To avoid the effect of load relaxation in the reference specimen on the separation parameter and the crack growing length estimation, the load was assumed to be maximum and constant value behind the peak load in the reference curve.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.