Abstract

In the present, a power decoupling method without additional component is proposed for a dc to single-phase ac converter, which consists of a flying capacitor dc/dc converter (FCC) and the voltage source inverter (VSI). In particular, a small flying capacitor in the FCC is used for both a boost operation and a double-line-frequency power ripple reduction. Thus, the dc-link capacitor value can be minimized in order to avoid the use of a large electrolytic capacitor. In addition, component design, of, e.g., the boost inductor and the flying capacitor, is clarified when the proposed control is applied. Experiments were carried out using a 1.5-kW prototype in order to verify the validity of the proposed control. The experimental results revealed that the use of the proposed control reduced the dc-link voltage ripple by 74.5%, and the total harmonic distortion (THD) of the inverter output current was less than 5%. Moreover, a maximum system efficiency of 95.4% was achieved at a load of 1.1 kW. Finally, the high power density design is evaluated by the Pareto front optimization. The power densities of three power decoupling topologies, such as a boost topology, a buck topology, and the proposed topology are compared. As a result, the proposed topology achieves the highest power density (5.3 kW/dm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ) among the topologies considered herein.