Abstract
Temperature plays a vital role in the machining industry today. NiCr/NiSi thin-film thermocouples have been deposited on the rake face of polycrystalline cubic boron nitride (PCBN) tools by magnetron sputtering. The typical deposition conditions are summarized. Static and dynamic calibrations of the NiCr/NiSi thin-film thermocouples are presented. The Seebeck coefficient of the TFTC is 37.3 μV/°C. The response time is about 3.9 ms. The testing results indicate that the developed NiCr/NiSi thin-film thermocouple sensors perform excellently when machining A3 steel in situ.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.