Abstract
ABSTRACT A cross-flow fluidized bed paddy dryer with a capacily of 200 kgh was designed, fabricated and tested. Experimental results showed that final moisture content of paddy should not be lower than 23 % dry-basis if quality is to be maintained. Drying air temperature was keot constant at 115°C according to the recommendation of previous work. Results obtained from the mathematical model developed in this study indicatedthat optimum operating parameters should be as follows : air speed of 2.3 m/s, bed thickness of 10 cm and fraction of air recycled of 80 %. At this condition, energy consumption was close to the minimum while drying capacity was near the maximum. A prototype fluidized bed dryer with a capacity of 1 t/h was designed, fabricated and installed with the collaboration of a private company. The unit has been used for almost the whole past harvesting season in 1994 at a paddy merchant sile with preference compared to conventional column continuous dryers. More than 300 tons of paddy were dried...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.