Abstract

For speed control of hydraulic elevators, inverter control systems have good characteristics for saving energy and improving efficiency. This paper describes a newly developed special valve for hydraulic elevators controlled by an inverter. This valve has two channels of a pilot circuit with a check valve. One is for normal use, and the other is for backup in case of an emergency such as a blackout. Simulations and experiments were carried out on the effects of the deceleration adjuster in the emergency pilot circuit, and it was confirmed that the car could be safely stopped.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.