One-step membrane-based competitive colloidal gold-based immunoassays in lateral-flow formats for the rapid detection of medroxyprogesterone acetate (MPA) were developed. Nitro-cellulose membrane strip was separately coated with goat anti-rabbit IgG (control line) and MPA hapten-OVA conjugate (test line). Anti-MPA polyclonal antibody labelled with colloidal gold particles was firstly incubated with MPA. A positive reaction as a result of the remaining antibody-gold conjugate combining with antigen coated on the membrane was obvious by visual detection, with detection limits for lateral flow of 5 µg/kg for detecting MPA standard solution, and the limit of detection was 10 µg/kg for detecting the MPA spiked in swine urine and liver. The assay time for test was less than 5 min, suitable for rapid testing on-site.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.