Abstract
We report on the optimized substrate pretreatment and deposition process conditions for boron-doped diamond (BDD) electrodes fabricated by hot-filament chemical vapor deposition (HFCVD). The optimized BDD electrode with a doping concentration of 8000 ppm showed high accuracy and precision in detecting Cd(II), Pb(II), and Cu(II) ions. In addition, this demonstrates excellent selectivity against external metal ions under the optimized stripping voltammetry measurement conditions. The detection limits of the target ions of Cd(II), Pb(II), and Cu(II) were 0.55 (±0.05), 0.43 (±0.04), and 0.74 (±0.06) μg/L (S/N = 3), respectively. In real samples spiked with 100 μg/L Cd(II), Pb(II), and Cu(II), both the accuracy and precision of the BDD electrode were within 5%; the interference with organic matter was also negligible. The excellent selectivity and long-term stability indicate that the BDD electrode developed in this study are potentially useful for online water environment monitoring systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.