Abstract

Prototype of efficient anode-off gas recycle blowers was developed with a 3D turbo impeller and a DC brush-less built-in motor for high efficiency SOFCs. Performance test of the blowers clarified 26% and 52% total blower efficiency for the type SSR-70 for 10 kW-class SOFC and SSR-140 for 250 kW, respectively. System performance simulation of an SOFC system with the SSR-70 blower elucidated that 59% net AC electrical efficiency can be expected. When the blower efficiency is improved to 50% as of SSR-140, electrical efficiency will become 60%. We will continue developing more efficient recycle blowers.