Abstract
The purity of hydrogen finally purified in the hydrogen purification process system is greatly influenced by the uniformity of the purification temperature of the dry tower. An in-house code that can be easily used by field designers has been developed to predict the capacity of the appropriate heat source and the time to reach the temperature of the dry tower. A code was developed to predict unsteady heat transfer using VBA. To verify the developed code, a grid independence test was performed, and finally, calculations were performed for two cases. The factor that influences the temperature history over time is the precise determination of values for the density, specific heat, and thermal conductivity of the heterogeneous materials composing the dryer tower. It was confirmed that the developed code well describes the actual test trend data of the regeneration process of adsorption and desorption, and it is judged that the code developed in the design process of various capacity systems will be effectively applied to the heat capacity calculation in the future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.