Abstract

An indirect immunofluorescent assay (IFA) to detect Ebola virus subtype Reston (EBO-R) antibodies was developed by the use of a HeLa cell line stably expressing EBO-R nucleoprotein (NP). This IFA has a high specificity for the detection of EBO-R IgG antibodies in both hyperimmune rabbit sera and monkey sera collected during an EBO-R outbreak in the Philippines in 1996. Furthermore, this IFA showed a higher sensitivity for the detection of EBO-R antibodies than did the IFA using HeLa cells expressing the NP of Ebola virus subtype Zaire. These results suggest that this new IFA is useful for seroepidemiological studies of EBO-R infection among monkeys.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.